Femoral component impacting

    The tibial implant and the femoral component are available (without cement, with porous tita- nium coating). The knee is flexed again and the final femoral component is impacted.

Closing efter surgery realized in three layers

    Aponevrosis and capsular, sub-cutaneous, cutaneous plans are sutured. With suction drain, splint.

Post-operative care

    - Removable splint,
    - Antiphlebitic prevention,
    - Early deambulation 1 day after operation with com
    - plete weight bearing, - Immediate work against muscular inhibition,
    - Flexion 2 or 3 days after operation at the time of the suction drain removal,
    - Active flexion assisted by physiotherapist up to 90°,
    - Motorized splint if painful inhibition,
    - Immediate implementation of walking pattern to eliminate the splint as of operation day + 7,
    - Deambulation with walking stick for 45 days.